  • 產(chǎn)品名稱:美國(guó)omega FMG812電磁流量計(jì)

  • 產(chǎn)品型號(hào):FMG812
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車
簡(jiǎn)單介紹:
美國(guó)omega FMG812電磁流量計(jì)由美國(guó)omega原廠渠道的深圳鑫博恒業(yè)科技有限公司特價(jià)提供,美國(guó)omega FMG812電磁流量計(jì)精度高,壽命長(zhǎng),美國(guó)omega FMG812電磁流量計(jì)是值得信賴的流量?jī)x表。
詳情介紹:

美國(guó)omega FMG812電磁流量計(jì)

塑料體電磁流量計(jì)
FMG800 Series
1年保修 新產(chǎn)品!
塑料體電磁流量計(jì)
FMG800 系列:塑料體電磁流量計(jì)
沒(méi)有移動(dòng)部件
*小直管段的要求
電池供電的
內(nèi)置的速度和總指標(biāo)
耐腐蝕
脈沖輸出(fmg810只)
美國(guó)加侖的預(yù)編程
(其他單位提供)
The FMG800 Series is a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 1, 2 and 3 inch pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals and fertilizers. It is light weight and easy to install or remove from the pipe for inspection*.
With no moving parts, the magmeter permits unobstructed flow, minimizing flow disturbances and straight pipe requirements. The FMG800 Series can be used in piping configurations where there is little space between the meter and an elbow or valve. The FMG800 Series is resistant to wear from sand and debris found in ground or surface water. Since there are no bearings or propeller to wear out, maintenance and repair costs are kept to a minimum and it tolerates high flows without damage. A hinged polyethylene cover is included that protects from dust and UV rays, while permitting easy access to the flow rate and total display. Flow rate and total can be displayed in a variety of units, but must be factory programmed.
The FMG800 Series is used for tracking flow rate and total flow in usage monitoring applications including wells, industrial wastewater, heap leach mining discharge, cooling tower deduct, turf, landscape, and other water reclamation applications. In the event of DC power loss, or when changing batteries, the FMG800 will retain internal settings and flow total.
FMG800 Series The FMG810 Series is externally powered via a 5-pin connector cable which also provides pulse output for use with a variety of Omega displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications.
The FMG800 Series is a battery-operated unit for use when pulse output is not required. The batteries are user replaceable with an approximate 1 to 2 year life depending on usage.
*Includes Omega NPT fitting kit on 2 and 3" models.
Specifications
Pipe Size: 1, 2 or 3" full port
Fittings: 1 NPTF, 2 or 3" flange clamps with 2 or 3 NPTF fitting kit
Metric (BSP) fittings optional
Pressure: 150 psi or 10.3 bar working pressure @ 21°C (70°F)
Operating Temperature Range: -12 to 54°C (10 to 130°F), -40 to 80°C (-40 to 176°F) non-operating
Accuracy: ±1% of reading (between 10% and 100% of max flow) ±3% of reading (between cutoff and 10% of max flow)
Flow Range Minimum:
1": 2.3 GPM (0.145 LPS)
2": 6 GPM (0.38 LPS)
3": 14 GPM (0.88 LPS)
Flow Range Maximum:
1": 110 GPM (6.94 LPS)
2": 300 GPM (18.9 LPS)
3": 670 GPM (42.3 LPS)
Materials Body: Glass-filled polypropylene
Electrodes: 316 stainless steel
Electronics Housing: Die-cast aluminum, powder-coated
Display Cover: Polyethylene
Display Digits: Rate-6, Total-8
Units Rate: Gallons/Minute, Cubic Feet/ Second, Acre-Feet, Acre-Inch, Gallons, Gallons x 1000, Cubic Feet/Minute, Liters/Second
Units total: Cubic Feet, Liters, Mega-liters, Cubic Metersm Liters/Minute, Cubic Meters/Minute
Power:
FMG800: 10 to 30 Vdc @ 60 mA max (15 mA average)
NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation
FMG810: 6 each “AA” alkaline cells (included), replaceable. Estimated life is 1 to 2 years depending on usage
Pulse Output (FMG810 Only):
Signal: Current sinking pulse, opto-isolated, 32 Vdc max at 10 mA max
Standard Pulse Rate: 1 unit/pulse out, pulse width of 10 ms depending on unit selection
High Frequency (-HF): Pulse width 1.1 ms, min/max frequency, 3 to 150 hz
Pulse/Unit: 1" = 80, 2" = 30, 3" = 13
Empty Pipe Detection: Hardware/ software, conductivity-based
Conductivity: >20 micro Siemens/cm
Environmental: NEMA 4X standard
Electrical Connection (FMG810 Only): 5-pin male circular with 6 m (20') cable


產(chǎn)品型號(hào) 產(chǎn)品描述
FMG801 1' battery powered magmeter
FMG802 2' battery powered magmeter
FMG803 3' battery powered magmeter
FMG811 1' DC powered magmeter
FMG812 2' DC powered magmeter
FMG813 3' DC powered magmeter
FMG811-HF 1' DC powered magmeter high frequency out
FMG812-HF 2' DC powered magmeter high frequency out
FMG813-HF 3' DC powered magmeter high frequency out
 

注釋: Comes complete with operator’s manual.
2" units also include 5-pin 6 m (20') cable and 2 NPT fitting kit.
3" units also include 5-pin 6 cm (20') cable and 3 NPT fitting kit.
Battery powered units come complete with 6 "AA" batteries.
For metric fittings add suffix, "-BSP" to the model number, no additional cost.

 美國(guó)omega FMG812電磁流量計(jì) 

標(biāo)題:
內(nèi)容:
聯(lián)系人:
聯(lián)系電話:
Email:
公司名稱:
聯(lián)系地址:
 
 
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!

粵公網(wǎng)安備 44030402001379號(hào)

主站蜘蛛池模板: 91精品国产高清一区二区三区 | 亚洲一区二区国产 | 国产女人久久精品 | 欧洲成人午夜免费大片 | 日本特黄aa一大片 | 日韩电影在线看 | 免费久久精品国产片香蕉 | 亚洲综合色婷婷在线观看 | 91高清国产视频 | 久草在线观看福利视频 | 欧美精品一区二区精品久久 | 久久se精品一区精品二区 | 日韩三级视频 | 日韩成人免费视频 | 国产精品成人第一区 | 精品视频在线观看视频免费视频 | 色婷婷综合久久久中字幕精品久久 | 中文字幕亚洲一区 | 日韩亚洲欧美一区 | 久久国产亚洲观看 | 亚洲五月综合网色九月色 | 99久久国产综合精品女小说 | 久久曰| 日本美女一区二区三区 | 一级做a免费视频 | 亚洲综合国产 | 亚洲精品无码成人A片色欲 亚洲欧美日韩激情在线观看 | 国产成人精品一区二区三在线观看 | 久草社区在线 | 婷婷开心六月久久综合丁香 | 久久久久亚洲精品中文字幕 | 六月婷婷综合 | 91精品国产一区二区三区 | 国产主播福利精品一区二区 | 91在线观| 欧美日韩综合一区 | 亚洲综合视频在线观看 | a级网站| 久久久国产视频 | 69国产成人精品午夜福中文 | 久久99热成人精品国产 |